Isolate and drain system to be descaled, making sure no raw water can be introduced during the process. Disable compressor or chiller to prevent operation during descaling. Flush system with fresh water to remove any remaining sea water prior to beginning.
Fill system with the required amount* of ready- to-use Descaling Fluid. Set up a recirculating system with a suitable pump in which both inputs and outputs feed/drain solution from a container or bucket (If unable to use a pump, you may also allow product to soak within the system for 4-8 hours). DO NOT seal the system off, as gassing will occur during the process and excess pressure may cause damage.
Drain solution from system and dispose in accordance with local, state and federal laws.
Flush system with fresh water to remove any remaining descaling fluid, and then reassemble properly. It is recommended to replace all sacrificial anodes at this time.
Fully submerge equipment in solution for 4-8 hours, or until scale has dissolved. Rinse with fresh water.
water, phosphoric acid and isopropy alcohol.
CORROSIVE. CAUSES IRRITATION OR BURNS TO SKIN, EYES, AND RESPIRATORY TRACT. MAY BE HARMFUL OR FATAL IF SWALLOWED. Contains: Water and Phosphoric Acid. Avoid contact with skin or eyes. Avoid breathing vapors or mists. Do not taste or swallow. Wash thoroughly after handling.
Star brite's liability is limited to the purchase price of this product.